The Biofunctional Prosthetic System in Complete Denture Fabrication: A Critical Narrative Review of Mechanisms, Clinical Evidence and Unresolved Questions

Review History

Published: 2026-09-19

DOI: 10.9734/bpi/mreca/v4/7945

Page: 87-117


Rajeshwari Yadav *

Department of Prosthodontics and Crown and Bridge, Swargiya Dadasaheb Kalmegh Smruti Dental College & Hospital, Maharashtra University of Health Sciences, Nagpur, Maharashtra, India.

*Author to whom correspondence should be addressed.


Abstract

Complete denture therapy remains the principal rehabilitative option for a large and, in absolute terms, growing population of edentulous adults, yet outcomes continue to vary widely between operators, laboratories and patients. Proprietary integrated workflows, of which the Biofunctional Prosthetic System is the most widely discussed example in removable prosthodontics, propose to reduce this variability by prescribing a fixed sequence of clinical and laboratory steps, matched instrumentation and injection polymerisation of the denture base. The present review examines whether the available evidence supports the claim that such an integrated system delivers clinically meaningful advantages over well-executed conventional fabrication, and whether the mechanisms proposed to explain any advantage are independently substantiated.

Literature was identified through open scholarly indexes and citation searching, with verification of bibliographic identity and digital object identifiers, and was appraised for design adequacy, outcome selection, comparator specification and generalisability. The synthesis is organised around the constituent elements of the workflow rather than around individual publications, because the system is a bundle of interventions whose components carry unequal evidential support.

Three findings emerge. First, the strongest independent evidence supports only one component of the bundle, namely injection polymerisation, which reduces processing-related dimensional and occlusal error under laboratory and semi-clinical conditions. Second, the small number of comparative clinical studies report advantages that are concentrated in operator-measured or laboratory-measured outcomes such as masticatory efficiency, while patient-reported outcomes are largely indistinguishable between the system and conventional fabrication. Third, every published comparison confounds several simultaneously altered variables, restricts recruitment to favourable anatomical presentations, or applies short observation periods, so that the effective ingredient of the bundle has not been isolated. Evidence from research on simplified fabrication protocols, face-bow use and occlusal scheme selection points in the opposite direction to the assumption that procedural elaboration reliably improves patient-perceived outcomes.

Confidence in the proposition that the system is superior to competent conventional practice is therefore limited. Priorities include component-dismantling trials, recruitment of anatomically compromised patients, longer observation, and economic evaluation appropriate to the health systems in which edentulism is concentrated.

Keywords: Complete denture, edentulous jaw, injection moulding, dental prosthesis design, patient-reported outcome measures, prosthodontics, oral health-related quality of life, denture bases


How to Cite

Yadav, R. (2026). The Biofunctional Prosthetic System in Complete Denture Fabrication: A Critical Narrative Review of Mechanisms, Clinical Evidence and Unresolved Questions. Medical Research: Emerging Concepts and Applications Vol. 4, 87–117. https://doi.org/10.9734/bpi/mreca/v4/7945